NG2U, NG3U, NG4U Inclinometers of high measuring accuracy with an integrated 0...5 Volt signal conditioner for inclination measurement in the ranges of ±10, ±30 and ±80 degrees |
Features
Description
The NG2U, NG3U and
NG4U are capacitive, liquid based inclinometers with integrated
sensor electronics and signal conditioner. Electronic temperature
compensation makes up for the temperature drift of the
sensitivity of the primary transformer. An integrated, highly
stable voltage regulator ensures stable operation for a range of
supply voltages.
The measurement technique provides a linear relationship between
the angle to be measured (up to (80 degrees for the NG4U) and the
output signal that is calibrated during manufacture. The
measuring time constant can be matched to the requirements of the
measurement task by appropriate hardware programming.
Application
The inclinometers
NG2U, NG3U and NG4U are suited for applications requiring high
measurement accuracy with low linearity deviation, low
temperature sensitivity and high long-term stability for
measurement of large inclination angles, returning a large output
signal while using a non-regulated supply voltage.
For particularly harsh operating conditions, we recommend the
sensor casing SB1U or the casing SB1S featuring additional switch
outputs.
These inclinometers have their application in areas such as
construction, mining, vehicles, aircraft, ships, surveying
equipment, transportation and conveyor systems and process
automation as well as safety engineering.
Technical Specifications
Type | NG2U | NG3U | NG4U |
Measuring range | ±10 degrees |
±30 degrees |
±80 degrees |
Resolution |
<0.001 degrees |
<0.003 degrees |
<0.01 degrees |
Standardized sensitivity (other standardizations on request) |
200mV / degree |
66.67mV / degree |
25mV / degree |
Linearity deviation |
<1·10-3F.S. |
||
Transverse sensitivity |
<0.5% at 45° tilt |
||
Settling time |
approx. 0.3 seconds (1s, 2s, 3s optional) |
||
Temperature drift of sensitivity |
<-0.01% / Kelvin |
||
Temperature drift of zero point |
<±10-3 degrees / K |
||
Supply voltage Ub |
9V ... 30V (optional 5V, regulated) |
||
Output voltage offset for sensor zero position |
2.5 Volt |
||
Current drawn |
approx. 5mA |
||
Degree of protection |
IP65 |
||
Operating temperature |
-40...+85°C |
||
Storage temperature |
-45...+90°C |
||
Weight (without clamping ring or cable) |
approx. 110 grams |
||
Standard electrical connection |
0.5m shielded cable Ø4.6mm, 4-wire other lengths optional |
On request: special ranges
Each sensor will be
delivered with individual calibration dates (offset, sensitivity)
and calibration record.
Dimensions (in mm) and Connections
Attention! Do not short circuit the supply voltage with one of the outputs. |
SEIKA Mikrosystemtechnik GmbH - Söllerweg1- D 87487 Wiggensbach - email: seika@seika.de - Tel.+49 8370 9290070 - FAX:+49 8370 9290079
H118S